Higher yields / Safe & Reliable / Smart / User-friendly
The series products adopt 2 MPP trackers design. Equipped with screw crimp terminal for DC and AC side, convenient installation and maintenance. With high detection accuracy, when the load power is less than 2%, the measurement accuracy is still high. In addition, it allows the system to be monitored and controlled remotely.
2 MPP tracker, Max. efficiency up to 98.5%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Anti-PID function (Optional)
- Model SUN-15K-G05
- PV String Input Date Max. PV Input Power(kW) 19.5 Max.
- PV Input Voltage(V) 1000
- Start-up Voltage(V) 250 MPPT
- voltage range(V) 250-850
- Rated PV Input voltage(V) 600
- Max. Input Short Circuit Current (A) 19.5+39
- Max. Operating PV Input Current(A) 13+26
- No. of MPP Trackers/No. of Strings per MPP Tracker 2/1+2
- AC Input/Output Side Rated AC Output Active Power(kW) 15
- Max. AC Output Apparent Power(kVA) 16.5
- Rated AC output current (A) 22.7/21.7
- Max. AC Output Current(A) 25/23.9
- Rated output voltage/range (V) 220/380V, 230/400V 0.85Un-1.1Un Grid Connection Form 3L/N/PE
- Rated Output Grid Frequency/range(Hz) 50/45-55, 60/55-65
- Power Factor Adjustment Range 0.8 leading to 0.8lagging
- Total Current Harmonic Distortion THDi <3% DC Injection Current <0.5%
- ln Efficiency Max. Efficiency 98.5%
- Euro Efficiency 98.0%
- MPPT Efficiency >99%
- Equipment Protection DC Polarity Reverse Connection Protection yes
- AC Output Overcurrent Protection yes
- AC Output Overvoltage Protection yes
- AC Output Short Circuit Protection Thermal Protection yes
- DC Terminal Insulation Impedance Monitoring yes
- DC Component Monitoring yes
- Ground Fault Current Monitoring yes
- Power Network Monitoring yes
- Island Protection Monitoring yes
- Earth Fault Detection yes
- DC Input Switch yes
- Overvoltage Load Drop Protection yes
- Residual Current (RCD) Detection yes
- Surge Protection Level TYPE II(DC),TYPE II(AC) Interface
- Communication Interface RS485/RS232 /WiFi/LAN
- General Data Operating Temperature Range (°C) -25 to +60℃, >45℃
- Derating Permissible Ambient Humidity 0~100%
- Permissible Altitude (m) 4000m Noise (dB) <40 dB(A)
- Ingress Protection(IP) Rating IP 65 Inverter Topology
- Non-Isolated Over Voltage Category OVC II(DC),OVC III(AC)
- Cabinet Size (WxHxD mm) 332mm*457mm*203mm(Excluding connectors and brackets)
- Weight [kg] 15
- Warranty [year] 5 years
- Type Of Cooling Intelligent Air Cooling
- Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G98, G99, VDE 4105
- Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2