Higher yields / Safe & Reliable / Smart / User-friendly
This new series of three-phase output inverter has wider range of 30kw, 33kw, 36kw than the original series, at the same time still got two integrated MPPTs, allowing two-array to input from different roof orientations. In addition, it allows the system to be monitored and controlled remotely.
2 MPP tracker, Max. efficiency up to 98.6%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Anti-PID function (Optional)
- Model SUN-30K-G04 SUN-33K-G04 SUN-35K-G04 SUN-36K-G04
- PV String Input Date Max. PV Input Power(kW) 39 42.9 45.5 46.8
- Max. PV Input Voltage(V) 1000 Start-up Voltage(V) 250 MPPT voltage range(V) 200-850 Rated PV Input voltage(V) 600
- Max. Input Short Circuit Current (A) 60+60 Max. Operating PV Input Current(A) 40+40
- No. of MPP Trackers/No. of Strings per MPP Tracker 2/3+3 AC Input/Output Side Rated AC Output Active Power(kW) 30 33 35 36
- Max. AC Output Apparent Power(kVA) 33 36.3 38.5 39.6 Rated AC output current (A) 45.5/43.5 50/47.8 53/50.7 54.5/52.2
- Max. AC Output Current(A) 50/47.9 55/52.6 58.3/55.8 60/57.4
- Rated output voltage/range (V) 220/380V, 230/400V 0.85Un-1.1Un Grid Connection Form 3L/N/PE
- Rated Output Grid Frequency/range(Hz) 50/45-55, 60/55-65 Power Factor Adjustment Range 0.8 leading to 0.8lagging
- Total Current Harmonic Distortion THDi <3% DC Injection Current <0.5%ln Efficiency Max. Efficiency 98.6% Euro Efficiency 98.1% MPPT Efficiency >99%
- Equipment Protection DC Polarity Reverse Connection Protection yes
- AC Output Overcurrent Protection yes
- AC Output Overvoltage Protection yes
- AC Output Short Circuit Protection yes
- Thermal Protection yes
- DC Terminal Insulation Impedance Monitoring yes
- DC Component Monitoring yes
- Ground Fault Current Monitoring yes
- Power Network Monitoring yes
- Island Protection Monitoring yes
- Earth Fault Detection yes
- DC Input Switch yes
- Overvoltage Load Drop Protection yes
- Residual Current (RCD) Detection yes
- Surge Protection Level TYPE II(DC),TYPE II(AC) Interface
- Communication Interface RS485/RS232 /WiFi/LAN
- General Data Operating Temperature Range (°C) -25 to +60℃, >45℃ Derating Permissible Ambient Humidity 0~100%
- Permissible Altitude (m) 4000m Noise (dB) ≤ 50 Ingress Protection(IP) Rating IP 65 Inverter Topology
- Non-Isolated Over Voltage Category OVC II(DC),OVC III(AC)
- Cabinet Size (WxHxD mm) 362mm*577mm*215mm(Excluding connectors and brackets)
- Weight [kg] 23 Warranty [year] 5 years Type Of Cooling
- Intelligent air cooling Grid Regulation IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105
- Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2