Higher yields / Safe & Reliable / Smart / User-friendly
The Deye 70-110K grid-connected inverter is suited for medium and large-scale commercial rooftops and ground-mounted solar PV system in which reliability and stability are important. the full series inverter has 30% DC input oversizing ratio and 10% AC output overloading ratio, offering a faster return on investment.
Max. 6 MPP trackers, Max. efficiency up to 98.8%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Type II DC/AC SPD
Anti-PID function (Optional)
AFCI function (Optional)
- Model SUN-70K-G03 SUN-75K-G03 SUN-80K-G03 SUN-90K-G03 SUN-100K-G03 SUN-110K-G03
- PV String Input Date Max. PV Input Power(kW) 91 97.5 104 135 150 150 Max. PV Input Voltage(V) 1000 Start-up Voltage(V) 250 MPPT voltage range(V) 200-850
- Rated PV Input voltage(V) 600 Max. Input Short Circuit Current (A) 60+60+60+60 60+60+60+60+60+60 Max. Operating PV Input Current(A) 40+40+40+40 40+40+40+40+40+40
- No. of MPP Trackers/No. of Strings per MPP Tracker 4/4+4+4+4 6/4+4+4+4+4+4 AC Input/Output Side Rated AC Output Active Power(kW) 70 75 80 90 100 110
- Max. AC Output Apparent Power(kVA) 77 82.5 88 99 110 121 Rated AC output current (A) 106.1/101.5 113.6/108.7 121.2/115.9 136.4/130.4 151.5/144.9 166.7/159.4
- Max. AC Output Current(A) 116.7/111.6 125/119.6 133.3/127.5 150/143.5 166.7/159.4 183.3/175.4
- Rated output voltage/range (V) 220/380V, 230/400V 0.85Un-1.1Un Grid Connection Form 3L+N+PE
- Rated Output Grid Frequency/range(Hz) 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz Power Factor Adjustment Range 0.8 leading to 0.8lagging
- Total Current Harmonic Distortion THDi <3% DC Injection Current <0.5%ln Efficiency Max. Efficiency 98.7% 98.8% Euro Efficiency 98.1% 98.2% MPPT Efficiency >99%
- Equipment Protection DC Polarity Reverse Connection Protection yes AC Output Overcurrent Protection yes AC Output Overvoltage Protection yes
- AC Output Short Circuit Protection yes Thermal Protection yes DC Terminal Insulation Impedance Monitoring yes DC Component Monitoring yes
- Ground Fault Current Monitoring yes Power Network Monitoring yes Island Protection Monitoring yes Earth Fault Detection yes DC Input Switch yes
- Overvoltage Load Drop Protection yes Residual Current (RCD) Detection yes Surge Protection Level TYPE II(DC),TYPE II(AC) Interface
- Communication Interface RS485/RS232 /WiFi/LAN General Data Operating Temperature Range (°C) -25 to +65℃, >45℃
- Derating Permissible Ambient Humidity 0~100% Permissible Altitude (m) 4000m Noise (dB) ≤ 55 Ingress Protection(IP) Rating IP 65 Inverter Topology
- Non-Isolated Over Voltage Category OVC II(DC),OVC III(AC) Cabinet Size (WxHxD mm) 826mm*516mm*312.7mm(Excluding connectors and brackets)
- Weight [kg] 81 Warranty [year]
- 5 years Type Of Cooling Intelligent air cooling
- Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
- Safety EMC/Standard IEC/EN 62109-1,IEC/EN 62109-2,IEC/EN 61000-6-1,IEC/EN 61000-6-2,IEC/EN 61000-6-3,IEC/EN 61000-6-4