Higher yields / Safe & Reliable / Smart / User-friendly The single-phase inverter is one of the best options for residential application thanks to its smaller size and local LCD display, buttons. Also, with built-in zero-export function (external CT is needed), it offers true ease and comfort for PV system operators and installers.

2 MPP tracker, Max. efficiency up to 97.5%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Anti-PID function (Optional)
Low start-up voltage of 80V

  • Model    SUN-3.6K-G04    SUN-4K-G04    SUN-4.2K-G04 SUN-4.6K-G04 SUN-5K-G04    SUN-5.2K-G04 SUN-6K-G04    SUN-6.2K-G04
  • Input Side Max. DC Input Power(kW)    4.7    5.2    5.46    5.98    6.5    6.76    7.8    8.06
  • Max. DC Input Voltage (V)    550 Start-up DC Input Voltage(V)    80 MPPT Voltage Range (V)     70-500 Rated PV
  • Input Voltage (V) 360 Max. Operating PV Input Current (A) 13+13 Max. Input Short Circuit Current (A) 19.5+19.5
  • No. of MPP Trackers/ No. of Strings per MPP Tracker 2/1+1 Output Side Rated AC Output Active Power (kW) 3.6    4    4.2    4.6    5    5.2    6    6.2
  • Max. AC Output Apparent Power (kVA) 3.96    4.4    4.62    5.06    5.5    5.27    6.6    6.68
  • Rated AC Output Current (A) 16.4/15.7    18.2/17.4    19.1/18.3    20.9/20    22.7/21.7    23.7/22.7    27.3/26.1    28.2/27
  • Max. AC Output Current (A) 18/17.2    20/19.1    21/20.1    23/22    25/23.9    26/24.9    30/28.7    31/29.7
  • Rated Output Voltage/Range (V) 220/230 0.85Un-1.1Un Grid Connection Form L/N/PE
  • Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
  • Power Factor Adjustment Range 0.8 leading to 0.8 lagging
  • Total Current Harmonic Distortion THDi <3% DC Injection Current <0.5%
  • Efficiency Max.Efficiency    97.3%    97.5%
  • Euro Efficiency    96.9%    97.0%
  • MPPT Efficiency    >99%
  • Protection DC Polarity Reverse Connection Protection Yes
  • AC Output Overcurrent Protection Yes
  • AC Output Overvoltage Protection Yes
  • AC Output Short Circuit Protection Yes
  • Thermal Protection Yes
  • DC Terminal Insulation Impedance Monitoring Yes
  • DC Component Monitoring Yes
  • Ground Fault Current Monitoring Yes
  • Power Network Monitoring Yes
  • Island Protection Monitoring Yes
  • Earth Fault Detection Yes
  • Overvoltage Load Drop Protection Yes
  • Residual Current (RCD) Detection Yes
  • Surge Protection Level TYPE II(DC), TYPE II(AC)
  • General Data Operating Temperature Range (°C) -25 to +65℃, >45℃
  • Derating Permissible Ambient Humidity 0-100%\
  • Permissible Altitude (m) 2000m Noise (dB) ≤35 dB(A)
  • Ingress Protection(IP) Rating  IP 65
  • Inverter Topology Non-Isolated  Over Voltage Category OVC II(DC), OVC III(AC)
  • Cabinet Size (WxHxD mm) 330×323×190 (Excluding Connectors and Brackets)
  • Weight (kg) 8
  • Warranty 5years
  • Type of Cooling Natural Cooling
  • Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G99, VDE-AR-N 4105