SUN-7/7.5/8/9/10K-G | 7-10kW | Single Phase | 2 MPPT
Higher yields / Safe & Reliable / Smart / User-friendly
The single-phase inverter is one of the best options for residential application thanks to its smaller size and local LCD display, buttons. Also, with built-in zero-export function (external CT is needed), it offers true ease and comfort for PV system operators and installers.
2 MPP trackers, Max. efficiency up to 97.7%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Anti-PID function (Optional)
Low start-up voltage of 80V
- Model SUN-7K-G SUN-7.5K-G SUN-8K-G SUN-9K-G SUN-10K-G
- PV String Input Date Max. PV Input Power(kW) 9.1 9.8 10.4 11.7 13
- Max. PV Input Voltage(V) 550 Start-up Voltage(V) 80 MPPT voltage range(V) 70-500
- Rated PV Input voltage(V) 360 Max. Input Short Circuit Current (A) 19.5+39 39+39
- Max. Operating PV Input Current(A) 13+26 26+26
- No. of MPP Trackers/No. of Strings per MPP Tracker 2/1+2 2/2+2
- AC Input/Output Side Rated AC Output Active Power(kW) 7 7.5 8 9 10
- Max. AC Output Apparent Power(kVA) 7.7 8.25 8.8 9.9 11
- Rated AC output current (A) 31.8/30.4 34.1/32.6 36.4/34.8 40.9/39.1 45.5/43.5
- Max. AC Output Current(A) 35/33.5 37.5/35.9 40/38.3 45/43 50/47.8
- Rated output voltage/range (V) 220/230 0.85Un-1.1Un Grid Connection Form L/N/PE
- Rated Output Grid Frequency/range(Hz) 50/45-55, 60/55-65
- Power Factor Adjustment Range 0.8 leading to 0.8lagging
- Total Current Harmonic Distortion THDi <3% DC Injection Current <0.5%ln Efficiency
- Max. Efficiency 97.7%
- Euro Efficiency 97.2%
- MPPT Efficiency >99%
- Equipment Protection DC Polarity Reverse Connection Protection yes
- AC Output Overcurrent Protection yes
- AC Output Overvoltage Protection yes
- AC Output Short Circuit Protection yes
- Thermal Protection yes
- DC Terminal Insulation Impedance Monitoring yes
- DC Component Monitoring yes
- Ground Fault Current Monitoring yes
- Power Network Monitoring yes
- Island Protection Monitoring yes
- Earth Fault Detection yes
- DC Input Switch yes
- Overvoltage Load Drop Protection yes
- Residual Current (RCD) Detection yes
- Surge Protection Level TYPE II(DC),TYPE II(AC) Interface
- Communication Interface RS485/RS232 /WiFi/LAN
- General Data Operating Temperature Range (°C) -25 to +65℃, >45℃
- Derating Permissible Ambient Humidity 0~100%
- Permissible Altitude (m) 2000m Noise (dB) ≤ 35 Ingress
- Protection(IP) Rating IP 65 Inverter Topology
- Non-Isolated Over Voltage Category OVC II(DC),OVC III(AC)
- Cabinet Size (WxHxD mm) 330*410*198.5(Excluding connectors and brackets)
- Weight [kg] 15.3
- Warranty [year] 5 years
- Type Of Cooling natural cooling
- Grid Regulation IEC 61727,IEC 62116,EN 50549,NRS 097,RD 140,UNE 217002,G99
- Safety EMC/Standard IEC/EN 62109-1,IEC/EN 62109-2,IEC/EN 61000-6-1,IEC/EN 61000-6-2,IEC/EN 61000-6-3,IEC/EN 61000-6-4